{"product_id":"surveying-laser-collimator-precision-optical-alignment-tool-for-survey-instrument-calibration","title":"Surveying Laser Collimator – Precision Optical Alignment Tool for Survey Instrument Calibration","description":"\u003cp\u003eThe Surveying Laser Collimator is a precision optical alignment instrument developed for professional surveying, laboratory inspection, and instrument verification. By providing a stable and accurately defined optical reference, it helps technicians check and adjust the line of sight of total stations, theodolites, levels, and other optical surveying instruments.\u003c\/p\u003e\n\u003cp\u003eDesigned as a compact \u003ca href=\"https:\/\/store.mountlaser.com\/collections\/collimator-survey-instruments\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003esurveying equipment calibration tool\u003c\/strong\u003e\u003c\/a\u003e, this collimator provides a practical solution for workshops, calibration laboratories, instrument service centers, and professional surveying equipment manufacturers. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSurveying Laser Collimator Key Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSingle-Position Optical Reference – Provides a fixed optical target for checking instrument sighting accuracy and line-of-sight alignment.\u003cbr\u003eHigh-Precision Reticle System – The calibrated reticle supports detailed observation of angular deviation during surveying instrument inspection.\u003cbr\u003eStable Bench-Top Configuration – A rigid structure helps reduce unwanted movement and vibration during calibration procedures.\u003cbr\u003eLong-Distance Simulation – The optical design can create an effectively distant target, allowing technicians to perform alignment checks without requiring an extremely long test range.\u003cbr\u003eWide Application Compatibility – Suitable for total stations, theodolites, automatic levels, optical levels, and other precision surveying instruments.\u003cbr\u003eProfessional Calibration Solution – Functions as a reliable surveying equipment calibration tool for equipment manufacturers, service laboratories, and field instrument maintenance teams.\u003cbr\u003eOptical \u0026amp; Photoelectric Integration – Optional camera and optical components can be incorporated for visual inspection and measurement applications.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0596\/9035\/2818\/files\/ac8fc88c6bf73b3bf2719075ce6bc431.jpg?v=1786430841\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSurveying Laser Collimator Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTotal Station Calibration – Check horizontal and vertical sighting accuracy and identify optical alignment deviations.\u003cbr\u003eTheodolite Inspection – Provide a stable reference for collimation and optical axis verification.\u003cbr\u003eLevel Instrument Testing – Assist with optical line-of-sight inspection and instrument adjustment.\u003cbr\u003eSurveying Equipment Service Centers – Use the system as a repeatable reference during equipment maintenance and calibration.\u003cbr\u003eSurvey Instrument Manufacturing – Support production-line inspection and final quality-control procedures.\u003cbr\u003eOptical Laboratory Testing – Provide a controlled optical reference for precision measurement and alignment work.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/store.mountlaser.com\/collections\/collimator-survey-instruments\" target=\"_blank\" rel=\"noopener\"\u003eSurveying Laser Collimator\u003c\/a\u003e Specification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"622\" height=\"342\" style=\"border-collapse: collapse; width: 466.52pt;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"269\" style=\"width: 201.75pt;\"\u003e \u003ccol width=\"353\" style=\"width: 264.75pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eParameter\u003c\/td\u003e\n\u003ctd class=\"et2\" width=\"353\" style=\"width: 264.75pt;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003eSingle-position Laser Collimator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"36\" style=\"height: 27.00pt;\"\u003e\n\u003ctd class=\"et3\" height=\"36\" width=\"269\" style=\"height: 27.00pt; width: 201.75pt;\"\u003eApplication\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003eOptical Alignment \u0026amp; Survey Instrument Calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eReticle Scale Accuracy\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003e40 arcseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eSimulated Working Distance\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003e10 m reference distance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eLine-Width Measurement Reference\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003e7 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eSimulated Target\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003eInfinite-distance optical target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"36\" style=\"height: 27.00pt;\"\u003e\n\u003ctd class=\"et3\" height=\"36\" width=\"269\" style=\"height: 27.00pt; width: 201.75pt;\"\u003eOptical Magnification\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003eApprox. 0.12×–2× with optional optical system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eOptical Working Distance\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003e55–180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eField of View\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003eApprox. 2.4–18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eOptical Tube Dimensions\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003eApprox. 115 mm × 40 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eOptional Camera\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003e1\/3\" color industrial camera\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eCamera Resolution\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003e600-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eMinimum Illumination\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003e0.001 Lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003e–10°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003e≤85% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd class=\"et3\" height=\"18\" width=\"269\" style=\"height: 13.50pt; width: 201.75pt;\"\u003eInstallation\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"353\" style=\"width: 264.75pt;\"\u003eBench-top \/ Fixed Position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Mountlaser","offers":[{"title":"Default Title","offer_id":47878812631218,"sku":null,"price":5999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0596\/9035\/2818\/files\/2Surveying_Laser_Collimator.jpg?v=1786433536","url":"https:\/\/store.mountlaser.com\/fr\/products\/surveying-laser-collimator-precision-optical-alignment-tool-for-survey-instrument-calibration","provider":"Mountlaser","version":"1.0","type":"link"}